Graco 313869K Manuale Utente

Navigare online o scaricare Manuale Utente per Spruzzatori per vernici Graco 313869K. Graco 313869K User's Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 0
Instructions/Parts
AirPro
EFX Automatic
Spray Gun
313869K
EN
Conventional, HVLP, HiTEch, and LVMP automatic guns for small component finishing
applications. For professional use only.
100 psi (0.7 MPa, 7 bar) Maximum Working Fluid Pressure
100 psi (0.7 MPa, 7 bar) Maximum Working Air Pressure
See page 3 for model information.
Important Safety Instructions
Read all warnings and instructions in this
manual. Save these instructions.
TI14428A
Guns with manifold
TI14427A
Guns without manifold
II 2 G c IIB T6
Vedere la pagina 0
1 2 3 4 5 6 ... 39 40

Sommario

Pagina 1 - Spray Gun

Instructions/PartsAirPro™ EFX AutomaticSpray Gun313869KENConventional, HVLP, HiTEch, and LVMP automatic guns for small component finishing application

Pagina 2 - Contents

Selection Charts 10 313869KModels Without ManifoldsGun AssemblyPart No. TypeIncludes: Orifice SizeConstruction of Needle Tip/Nozzle ExitFluid Adjustme

Pagina 3 - 313869K 3

Selection Charts313869K 11Air Caps* Maximum compliant HVLP inlet pressure.Sample Pattern Sizes and Shapes* Fluid viscosity for these samples was 30 ce

Pagina 4 - Warnings

Installation 12 313869KInstallationThis spray gun can spray most coatings or fin-ishes currently being used for small compo-nent plastic, wood and met

Pagina 5 - 313869K 5

Installation313869K 13Guns without ManifoldThe gun is shipped ready for use in a circulat-ing system, with a fitting installed in each fluid port. Con

Pagina 6 - 6 313869K

Installation 14 313869KMount GunReciprocating Arm Rod MountTo mount the gun on a reciprocating arm rod [0.75 in. (19 mm) diameter maximum], insert the

Pagina 7 - 313869K 7

Setup313869K 15SetupConnect Air LineNOTE:•If your regulated air source does not have a filter, install an air filter (G) on each air line to ensure a

Pagina 8 - Selection Charts

Setup 16 313869KFIG. 6: Remote Air Regulation using Solenoid (Guns with Manifold)TI14444AFAN AIRCYLINDER AIRATOMIZING AIR2-way solenoid valve3-way sol

Pagina 9 - Models With Manifolds

Setup313869K 17Connect Fluid HoseNOTE:•Before connecting the fluid line, blow it out with air and flush it with solvent. Use solvent that is compatibl

Pagina 10 - Models Without Manifolds

Setup 18 313869KFlush Spray GunBefore running any paint through the spray gun: 1. Flush the gun with a solvent that is compat-ible with the fluid to b

Pagina 11 - Air Caps

Setup313869K 19NOTE: A larger fluid nozzle at a reduced fluid pressure will maintain the same flow rate, but the fluid stream (velocity) will slow dow

Pagina 12 - Installation

2 313869KContentsModels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Warnings . . . . . . . . . . . . . . . . . . . .

Pagina 13 - Ground System

Operation 20 313869KOperationPressure Relief Procedure1. Turn off all bleed type air valves and all other air and fluid supplies to the gun.2. Trigger

Pagina 14 - Mount Gun

Operation313869K 21Daily Gun CareNOTICEMethylene chloride with formic or propionic acid is not recommended as a flushing or cleaning solvent with this

Pagina 15 - Connect Air Line

Operation 22 313869KGeneral System Maintenance•Follow the Pressure Relief Procedure, page 20.•Clean the fluid and air line filters daily.•Check for an

Pagina 16 - Air regulator

Operation313869K 23

Pagina 17 - Connect Fluid Hose

Troubleshooting 24 313869KTroubleshootingProblem Cause SolutionSpray Pattern Normal pattern. No action necessary.Spray Pattern Dirty or damaged air ca

Pagina 18 - Adjust Spray Pattern

Troubleshooting313869K 25Gun spitting. Air getting into paint stream. Check if fluid source is empty and fill.Tighten fluid nozzle (4).Check fluid noz

Pagina 19 - HVLP Guns:

Service 26 313869KServiceNOTE: Numbers in parenthesis in the text refer to the reference numbers in the figures and in the parts list.Disassembly1. Fo

Pagina 20 - Operation

Service313869K 276. Use a 1/16 hex wrench to loosen the fluid needle set screw (7a). Remove the needle (6) from the piston (7).7. Check the fluid need

Pagina 21 - Daily Gun Care

Parts 28 313869KParts5a5b5c215d41716267a7b1015141213201918111215c5b5a5d415141513267b71011ti14447ati14448ati14945a7a132037Ultra-precision knobIndexingk

Pagina 22 - Clean and Flush Gun

Parts313869K 29Parts in Common Additional Parts for Models with Manifold----- Not sold separately.✓ Included in Air Cap Seal Kit 289791. See Repair Ki

Pagina 23 - 313869K 23

Models313869K 3Models* Needle tip and nozzle exit constructed from tungsten carbide.** Models with manifold have fully stainless steel fluid passages.

Pagina 24 - Troubleshooting

Repair Kits 30 313869KRepair Kits* Needle tip and nozzle exit constructed from tungsten carbide.Spray TypeGun Part NumberNozzle OrificeSizein. (mm)Nee

Pagina 25 - 313869K 25

Accessories313869K 31AccessoriesKit 24C216, Fittings (1/4 inch)Kit 24D143, Robot Adapter KitFanuc Paint Mate 200Compatible with and without manifold.K

Pagina 26 - Disassembly

Accessories 32 313869K

Pagina 27 - Reassembly

Dimensions313869K 33DimensionsGuns with ManifoldGuns without ManifoldFIG. 204.9 in. (124.5 mm) with Ultra-Precision knob4.1 in. (104.1 mm) with indexi

Pagina 28 - 28 313869K

Mounting Hole Layouts 34 313869KMounting Hole LayoutsGuns with ManifoldFIG. 22ti14441a 0.43 in.(10.9 mm) 0.86 in.(21.8 mm) 1.22 in.(31.0 mm)3 x M8 x 1

Pagina 29 - Kits, page 30

Mounting Hole Layouts313869K 35Guns without ManifoldFIG. 23 0.95 in.(24.1 mm) M8 x 1.25 T0.35 in. (8.9 mm) deepti14701a0.13 slot(3.3 mm) 1.76 in.(44.7

Pagina 30 - Repair Kits

Technical Data 36 313869KTechnical DataMaximum working fluid pressure 100 psi (0.7 MPa, 7 bar)Maximum working air pressure 100 psi (0.7 MPa, 7 bar)Max

Pagina 31 - Accessories

Technical Data313869K 37Triggering SpeedThese values apply to a new gun with a 12 ft. (3.6 m), 1/4 in. (6.3 mm) OD cylinder air line and a 0.043 in. n

Pagina 32 - 32 313869K

Air Flow 38 313869KAir FlowSee the chart to determine air consumption. Add the air consumption values shown for the atom-izing air and fan air to get

Pagina 33 - Dimensions

Air Flow313869K 39Spray Pattern Test ReportEvery AirPro EFX gun must pass a spray pattern test. The test report is printed and shipped in the box with

Pagina 34 - Mounting Hole Layouts

Warnings 4 313869KWarningsThe following warnings are for the setup, use, grounding, maintenance, and repair of this equip-ment. The exclamation point

Pagina 35 - Guns without Manifold

All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves th

Pagina 36 - Technical Data

Warnings313869K 5EQUIPMENT MISUSE HAZARDMisuse can cause death or serious injury.•Do not operate the unit when fatigued or under the influence of drug

Pagina 37 - Sound Data

Warnings 6 313869KTOXIC FLUID OR FUMES HAZARDToxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or s

Pagina 38 - Air Flow

Warnings313869K 7

Pagina 39 - Spray Pattern Test Report

Selection Charts 8 313869KSelection ChartsTERMSLight Fluid: Up to 18 seconds with No. 2 Zahn cup (20 centipoise)Medium Fluid:19 to 28 seconds with No.

Pagina 40 - Graco Information

Selection Charts313869K 9Models With ManifoldsGun AssemblyPart No. TypeIncludes: Orifice SizeConstruction of Needle Tip/Nozzle ExitFluid Adjustment Kn